🎥 The video is part of a series on potentiometry and pH measurement.
💻 The video discusses the experimental measurement of pH and the calibration of two points.
🔬 The video mentions the collaboration of Professor Ademar and other contributors in the creation of the material.
📌 pH measurement and control are crucial in various fields, including water production and food cultivation.
⚡ Using a pH meter provides faster, cost-effective, and numerically reliable results compared to other methods.
🔬 This video will cover the fundamental procedures of pH measurement, including system limitations, common measurement errors, and troubleshooting techniques.
📊 The video discusses the calibration of pH meters and the importance of ensuring measurement reliability.
🧪 Multiple calibration methods, including using two standards and obtaining a calibration curve, are explored.
⚖️ The advantages, disadvantages, and limitations of different calibration approaches are analyzed.
🧪 The experimental measurement of pH using pHmetry requires calibration with two buffer solutions.
🔬 Before each measurement, the glass combined electrode must be washed and dried to avoid contamination.
⚖️ The potential reading at pH 7 is recorded and used as a reference for calibration with the pH 4 buffer solution.
🔑 The electrode buffer needs to be washed and dried before taking readings.
🔎 The equipment calculates and displays the percentage of response factor and the pH 0.
📈 The equipment calculates and shows the slope percentage of the obtained line equation.
📊 The experimental measurement of pH involves calibrating the equipment using two standards.
⚙️ A developed experimental system allows for the calculation of the calibration curve using the difference in potential and the difference in pH.
💡 The electrode's response is evaluated by comparing the calculated pH value with the theoretical pH value, and a tolerance of up to 90% is acceptable.
🔍 The electrode function should always be fully immersed in the solution for accurate pH readings.
⚖️ Calibration of the equipment is essential, and readings should closely match the calibrated value.
🔬 After stabilizing, the direct reading of the sample on the calibrated equipment is around pH 2.40 and 277 MV.
Luxembourg student visa 2021 | Luxembourg student visa process | easy study visa 2021 | Major Kamran
ONE language, THREE accents - UK vs. USA vs. AUS English! (+ Free PDF)
A História do futebol – The Beautiful Game Africa 2001 (11 13)
تركيا الآن مشلولة! بعد الزلزال طوفان كالجبال يفاجئ الناس! لم تشهد اسطنبول مثل هذه الفيضانات من قبل!
The Story of the First Video Game Cartridge
Meme Coin and Dextools Master Class